FAQ
What does the UDOS001/007 Micro Dosimeter measure?
• The Micro Dosimeters directly measure total ionizing dose absorbed by an internal silicon test mass simulating the silicon die of spacecraft ICs.
• Radiation measured includes electrons, protons, and gamma rays; the device measures energy absorbed in the silicon detector, not incident energy directly.
• Measurement range extends to 40 krad(Si) with dose resolution of 15 urad(Si) per step.
What is the difference between UDOS001 and UDOS007?
• UDOS007 is the High LET extended temperature range version.
• UDOS007 incorporates a raised energy level input threshold allowing accumulation of higher levels of detected ionizing radiation.
• UDOS007 has an extended operating temperature range: -30 to +70 degrees C versus -30 to +40 degrees C for UDOS001.
What outputs does the Micro Dosimeter provide?
• Low range (Pin 5): 15 urad(Si)/19.5 mV step, 0-3.8 mrad range.
• Medium range (Pin 6): 256x Low range, 0-0.98 rad range.
• High range (Pin 7): 256x Medium range, 0-252 rad range.
• Pseudo-logarithmic output (Pin 8): 0-40 krad(Si) range for low-rate total dose monitoring.
What is the patented integrator architecture and why does it matter?
• The patented integrator architecture produces a flat energy response to ionizing radiation across the measurement energy range.
• A flat energy response means consistent dose measurement accuracy regardless of the energy of the incident particles.
• This makes UDOS001/007 the first compact microcircuit providing repeatable TID measurement over a wide range of radiation energies.
How do the Micro Dosimeter outputs connect to spacecraft systems?
• Analog outputs connect directly to standard ADCs or spacecraft housekeeping analog inputs in the 0-5V range.
• Minimal host vehicle demands -- no special interface hardware required.
• DAC output impedance is 8-12 kilohms; outputs should be connected to high impedance ADC or buffered.
What screening and qualification is available?
• Commercial grade (electrical test only): UDOS001-C and UDOS007-C.
• Class H-equivalent MIL-PRF-38534 screening: UDOS001-H and UDOS007-H.
• Class H screening includes internal visual, temperature cycling (-65 to +150 degrees C x10), constant acceleration 3,000 G, burn-in 160 hours at 125 degrees C PDA 10%, seal, and electrical test at min/max/room temperature.
What radiation survivability has the Micro Dosimeter demonstrated?
• Xenon-beam testing at Lawrence Berkeley Labs demonstrated latch-up immunity up to 67.8 LET (MeV-cm2/mg).
• Harsh proton susceptibility testing showed no degradation of UDOS001 up to 40 krad(Si).
• The dosimeter measures across the full 40 krad(Si) range without functional degradation.
Can the Micro Dosimeter be mounted at multiple locations on a spacecraft?
• Yes. The compact 1.4 x 1.0 x 0.2 inch package and 20-gram weight support mounting at multiple locations.
• Multi-location mounting enables spatial dose mapping to characterize shielding effectiveness across the spacecraft.
• Positioning and area shielding can be used for directional mapping of radiation events.